High resolution mass spectrometry

GINYS-ICIQ-003
The High Resolution Mass Spectrometry Unit (HRMS) offers access to state-of-the-art mass spectrometry instruments capable of characterizing the wide range of compounds that are usually of interest to the Institute. The apparatus includes most of the ionization options, introduction of chromatographic samples and techniques that are necessary to solve problems of mass spectrometry in chemistry. In addition to the characterization of pure samples, the unit also supports research projects that depend more on mass spectrometry experiments, such as mechanical studies, intermediate identification, characterization of impurities or biochemical applications. In addition, the Unit offers a comprehensive training to guarantee an optimal use of the installations and an adequate interpretation of the data.

Services

Autoflex™ mass spectrometer: MALDI-TOF-MS
m/z up to 70,000
Peptides and
Proteins, Polymers, Oligonucleotides
Low
molecular weight molecules
MaXis Impact™mass spectrometer (Bruker
Daltonics) with ESI and APCI ionization sources. Coupled to an Acquity™ UPLC (Waters).
ESI-QqTOF-MS
ESI: Polar
molecules, high and low molecular weight compounds.
Proteins
Organometallics.
Non-Covalent
Interactions
MS/MS analysis.
APCI- QqTOF-MS
Medium
Polarity Compounds, m/z up to 1500
MicroTOF™ mass spectrometer (Bruker Daltonics)
with ESI, APCI and Coldspray ionization sources. Coupled to an Ultimate3000™
HPLC (Thermo Scientific).
TOF-MS
Coldspray ionization:
analysis of ionic compounds at low temperature (until -100 ºC).
Labile species,
organometallic compounds, reaction intermediates.
ESI/MALDI dual source and Coldspray Ionization
coupled to ion mobility (IM)
Coldspray ionization-Ion
Mobility-MS: Unique combination for the analysis of ionic compounds at low
temperature (up to -100 ºC), including separation of isomers.
 MALDI
Imaging – Ion Mobility-MS: Isomers separation / Isobaric ions. Localization of
ions on tissues.

Equipment

  • Elute UHPLC-timsTOF flex™ mass spectrometer (Bruker Daltonics) ESI/MALDI dual source and Coldspray Ionization coupled to ion mobility (IM).
  • Coldspray ionization-Ion Mobility-MS: Unique combination for the analysis of ionic compounds at low temperature (up to -100 ºC), including separation of isomeric ions.
  • MALDI Imaging – Ion Mobility-MS: Isomers separation / Isobaric ions. Determination of ions on surfaces.
  • Liquid chromatograph coupled time-of-flight mass spectrometer
    Waters Alliance HPLC coupled to MicroTOF Focus (Bruker Daltonics) with electrospray (ESI) and atmospheric pressure chemical ionization (APCI) options.
  • Liquid chromatograph coupled time-of-flight mass spectrometer
    Waters LCT Premier liquid chromatograph coupled time-of-flight mass spectrometer (HPLC/MS-TOF) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) options.
  • MALDI time-of-flight mass spectrometer
  • BRUKER Autoflex matrix assisted laser desorption ionization (MALDI) time-of-flight mass spectrometer.
    Liquid chromatograph coupled quadrupole-time-of-flight mass spectrometer. (UPLC-QqTOF).
  • Waters liquid chromatograph (UPLC) coupled to MaXis Impact (Bruker Daltonics) hybrid analyzer: quadrupole-time-of-flight mass spectrometer (UPLC/MS-QqTOF) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) options.

Staff

Technician
Carly Chedotal | cchedotal@iciq.es | 977 920 200 (ext. 302)
Technicien
Vanessa Martínez | vmartinez@iciq.es | 977 920 200 (ext. 302)
Manager
Dr. Noemí Cabello | ncabello@iciq.es | 977 920 200 (ext. 302) | ORCID | PRC Page

INSTITUTE

ICIQ - Institut Català d'Investigació Química

Av. Països Catalans, 16

43007 Tarragona http://www.iciq.es/

DOMAINS RIS3CAT

  • Sistema d'energia i recursos
  • Education and knowledge generation system
  • Industrial system

CATEGORIES

  • TECHNOLOGICAL EQUIPMENT
    • Spectrometry, chromatography and spectroscopy

RATES AND ACCESS

Availability Level: High
Access Procedures:
Open